Product Thermal Capacity: 1 - 20 t/h
Working Pressure: 0.7 - 2 Mpa
Available Fuel: Nature gas, coke oven gas, biogas, methanol, liquid propane gas, diesel, heavy oil, light oil, crude oil, etc.
Available Industries: Heat supplying, chemical, food, textile, printing and dyeing, cigarettes and tobacco, fodder, pharmacy, building materials, brewery, rubber, hospital etc.
WNS series horizontal internal combustion boiler is a boiler shell type 3 passes wetback oil/gas fired boiler. After fuel is being atomized by burner, flame is full of the wave furnace and transfer heat via furnace wall, this is 1st pass; the high temperature smoke is collected in reversal chamber and then enters 2nd pass which is grooved tubes bundle area; after heat convection, air temperature gradually falls and goes to front smoke box and turn to 3rd pass, which is smooth tubes bundle area, and then enters chimney passing back smoke box and exhausted to the atmosphere.
1. Digitized manufacture
The key part such as material cutting, rolling, drilling are proceeded by advanced CNC machining process to reduce the assemble stress and extend boiler working lifetime.
The front and back smoke chamber plates are cut by CNC plasma cutting machine and looks tidy and beautiful.
2.Easy operation and maintenance
Fully automatically operating, with automatically adjustment and protection of burning, water level, temperature and steam pressure.
3. Longer working life
Smoke tube and tube sheet connection is expanded first to eliminate the gap between them, then adopt automatic argon arc welding to relief the stress and expand boilers working life.
Longitudinal and girth joint adopt advanced automatic submerged-arc welding for good welding quality. All longitudinal and girth joint will have 100% radiographic inspection.
Fin tube us ND steel or stainless-steel material which avoid low temperature corrosion.
Inspection procedure point is set up to guarantee the sequence of expanding and welding, avoid cracking of the tube sheet holes.
4. Less fuel consumption
High quality aluminum silicate fiber is used with fire clay insulation, to control the boiler body temperature below 45℃ to control heat lost.
Sufficient steam storage room and heating area makes boiler to generate high quality steam and high thermal power.
Condenser is added to reuse the waste heat of the exhausted smoke to increase feeding water’s temperature and reduce emission temperature, which can increase the thermal efficiency above 98% and save operating cost.
complete with fuel fired burner, pressure and level controls, as well as electronic control and monitoring system. All Johnston boilers are built to strict ASME guidelines whether it is Section 1 or Section 4 design. The boiler is of a wet back design with a fully submerged combustion chamber and firing tube. It …
With the fire tube boiler design, the water surrounds the heat source. In a water tube design, the heat source surrounds the water. Let’s elaborate on this difference and why it’s important. Conventional Fire Tube Design. With any boiler system, the creation of steam starts with the burner.
May 29, 2020· 🔴 Study Music 24/7, Focus Music, Meditation Music, Studying Music, Concentration Music, Work, Study Yellow Brick Cinema - Relaxing Music 722 watching Live now
· Web viewThis section specifies packaged fire tube boiler with trim (accessories), dual fuel (natural gas and No. 2 oil) burner, fuel valve and piping trains, //flue gas economizer,// and other accessories. A complete listing of common acronyms and abbreviations are included in Section 23 05 10, COMMON WORK RESULTS FOR BOILER PLANT AND STEAM GENERATION.
Package Boiler. Packaged boiler is the most common and efficient type of fire tube boiler used in industry to produce steam and hot water. This boiler delivers to site as a whole package factory assembled. The package boiler only requires electricity, water, steam and fuel connections and it …
D type water tube boiler. In the water tube boiler, the water and steam flow inside the tubes and the hot gases flow over the outside surfaces. Where as in fire tube boilers hot gases from combustion travels through the tubes. flue gases produced from furnace where fuel is …
The HDR(S)-RF burner has led the way to larger firetube boiler sizes, up to 2,600 BHP. Click here for the HDR-RF Register Burner quote form for a price or to contact us for your needs or questions. The versatility and flexibility of Webster’s Series HDR(S)-RF burners save time and money.
Kewanee Manuals. OEM Boiler Parts provides the manuals below free of charge as a courtesy to our valued customers. Kewanee F Burner Manual Download PDF Kewanee PhoenX LE Burner Manual Download PDF Kewanee PhoenX Burner Manual Download PDF Kewanee Firebox Boiler Manual Download PDF Kewanee Classic III Boiler Manual Download PDF.
Author: wareboilers Introduction. Fire tube boilers, also known as smoke tube boilers, are the most common type of industrial boiler employed today. Compared to water tube boilers, they are much more suitable for smaller plant applications because they can better cope with sudden high demand steam fluctuations.. Combustion occurs within a furnace with the exhaust gasses (flue-gasses) passing through a series of
For large commercial and industrial firetube and watertube boilers in BTU ranges from 8.4 MM BTU/hr to 63 MM BTU/hr, Webster’s HDS Series burner is the workhorse of these types of applications, offering dual fuel support, high turndown, low NOx, and high combustion efficiency.
Horizontal Return Tubular Fire Tube Boiler. As one of the oldest and most simple designs for … A/E Name Issue Description. A/E Project No.Month 00, 0000. The University of Texas FIRE TUBE STEAM BOILERS . MD Anderson Cancer Center23 52 39 . MS2020051510 OF 10
No. 76, Xin Da Road, Zhou tie Town, Yixing, Wuxi, China
0086-510-68530066, +86-13506151292