MENU
products
  1. Home
  2. --
  3. Industrial boilers

heat recovery hot water boiler

Product Thermal Capacity: 1 - 20 t/h

Working Pressure: 0.7 - 2 Mpa

Available Fuel: Nature gas, coke oven gas, biogas, methanol, liquid propane gas, diesel, heavy oil, light oil, crude oil, etc.

Available Industries: Heat supplying, chemical, food, textile, printing and dyeing, cigarettes and tobacco, fodder, pharmacy, building materials, brewery, rubber, hospital etc.

Get a Quote Send Message

Introduction of WNS gas / oil fired steam boiler:

WNS series horizontal internal combustion boiler is a boiler shell type 3 passes wetback oil/gas fired boiler. After fuel is being atomized by burner, flame is full of the wave furnace and transfer heat via furnace wall, this is 1st pass; the high temperature smoke is collected in reversal chamber and then enters 2nd pass which is grooved tubes bundle area; after heat convection, air temperature gradually falls and goes to front smoke box and turn to 3rd pass, which is smooth tubes bundle area, and then enters chimney passing back smoke box and exhausted to the atmosphere.

Technical advantages:

1. Digitized manufacture
The key part such as material cutting, rolling, drilling are proceeded by advanced CNC machining process to reduce the assemble stress and extend boiler working lifetime.
The front and back smoke chamber plates are cut by CNC plasma cutting machine and looks tidy and beautiful.

2.Easy operation and maintenance
Fully automatically operating, with automatically adjustment and protection of burning, water level, temperature and steam pressure.

3. Longer working life
Smoke tube and tube sheet connection is expanded first to eliminate the gap between them, then adopt automatic argon arc welding to relief the stress and expand boilers working life.
Longitudinal and girth joint adopt advanced automatic submerged-arc welding for good welding quality. All longitudinal and girth joint will have 100% radiographic inspection.
Fin tube us ND steel or stainless-steel material which avoid low temperature corrosion.
Inspection procedure point is set up to guarantee the sequence of expanding and welding, avoid cracking of the tube sheet holes.

4. Less fuel consumption
High quality aluminum silicate fiber is used with fire clay insulation, to control the boiler body temperature below 45℃ to control heat lost.
Sufficient steam storage room and heating area makes boiler to generate high quality steam and high thermal power.
Condenser is added to reuse the waste heat of the exhausted smoke to increase feeding water’s temperature and reduce emission temperature, which can increase the thermal efficiency above 98% and save operating cost.

Heat Recovery Chillers | Carrier Commercial Systems Nor

When there is a simultaneous need for chilled water and hot water, these chillers have the capability to operate in heat recovery mode. The recovered heat can be redirected for various heating applications, which saves energy while maintaining conditions. Learn More About Heat Recovery.

Waste Heat Recovery Systems, Boilers, Hot Water Generato

Waste Heat Recovery Systems, Waste Heat Recovery Boilers, Hot Water Generators, Thermic Fluid Heaters, Manufacturer, Supplier, Exporter, Services, Pune, Maharashtra

Waste Heat Recovery Boiler, Waste Heat Steam / Hot Wat

Chemical Industry Waste Heat Boiler 50-120 t/35-84 MW Pressure: ≤9.81MPa Coking Waste Heat Boiler 2-35 t/1.4-24.5 MW Pressure: ≤2.5MPa Sinter Cooler Waste Heat Boiler 2-35 t/1.4-24.5 MW Pressure: ≤2.5MPa Waste Heat Recovery Boiler of Hazardous Waste Incineration 2-35 t/1.4-24.5 MW

Heat Recovery – Illingworth Engineering Compa

Cain Industries Heat Recovery Systems. Boiler Economizer SystemsHeat Transfer Systems for Boiler Exhaust RecoveryCain Industries offers an extensive selection of boiler economizers specifically designed to recover BTU exiting the exhaust stack and transfer it back… Read More

Hot Water Recovery Time Calculator – MyBoiler.c

Hot Water Recovery Time Calculator. The above calculator is for calculating hot water recovery time for hot water cylinders. However it can be used to calculate general hot water recovery time for any amount of water. PowerKW is the power level of the heat source ie a 30 kw boiler would be 30 kw. Hot Water Recovery Power Required Calculator.

HEAT RECOVERY FROM CHILLED WATER SYSTE

HOT WATER SYSTEMS How can the recovered heat be used? Heat from hot water can be used for many purposes in the building or for process applications. In particular, hot water can be used for heating the building, heating service water or as part of a manufacturing or industrial process. There are many examples of each of these heating needs.

Blowdown Heat Recovery Systems for Boile

Hot, High-pressure continuous blowdown water drained from the boiler, contains valuable heat energy. The continuous blowdown process helps control boiler water quality and operating efficiency by removing suspended and dissolved solids from the water in the boiler drum.

Boiler, Gas oil boiler, Wood boiler, Thermal Oil Heat

Steam boiler and hot water boiler is common seen in hospital, here we mainly discuss the steam boiler usage in hospital. Steam boiler in hospital mainly used to sterilize medical vessels and dry matched bedding and cloths, as well supply hot water for bathing and …

Industrial Boilers Heat Recovery Steam Generators - Clayt

The bare tube coil design allows the industrial boilers heat recovery generators to operate at temperatures as high as 850°F in a dry condition. Call today to learn more about Clayton Exhaust Gas Boilers and industrial boilers heat recovery steam generators. Clayton Waste Heat Boilers

Waste Heat Recovery Boilers WHRB WHRG | Superior Boil

Superior Boiler offers waste heat recovery boilers in three basic designs to provide the greatest flexibility of any manufacturer in selecting a unit that is designed to meet the specific requirements of each application. Boiler designs are customized for specific job conditions to provide optimum performance and maximum energy savings.

Heat Recovery Water Heaters & Pool Heaters | Solar A

Heat Recovery Water Heating - Free Hot Water From AC/Heat Pump Domestic Water Heating A full range of HotSpot retrofit heat recovery systems is available for any size AC, heat pump, walk-in cooler, walk-in freezer or other refrigeration system with a capacity from 1 ton to 100 tons.

Contact Us

zhulin@zozen.com

No. 76, Xin Da Road, Zhou tie Town, Yixing, Wuxi, China

0086-510-68530066, +86-13506151292

Get Latest Price
Get in Touch

If you have any problems about our product and service,please feel free to give your inquiry in the form below. We will reply you within 24 hours as soon as possible.Thank you!

  • Boiler type
  • Name
  • email
  • Phone or Whatsapp
  • message
I accept the Data Protection Declaration

Copyright © 2020.Zhongzheng Boiler Co., ltd. All rights reserved.

top