boiler gas operated

Product Thermal Capacity: 1 - 20 t/h

Working Pressure: 0.7 - 2 Mpa

Available Fuel: Nature gas, coke oven gas, biogas, methanol, liquid propane gas, diesel, heavy oil, light oil, crude oil, etc.

Available Industries: Heat supplying, chemical, food, textile, printing and dyeing, cigarettes and tobacco, fodder, pharmacy, building materials, brewery, rubber, hospital etc.

Get a Quote Send Message

Introduction of WNS gas / oil fired steam boiler:

WNS series horizontal internal combustion boiler is a boiler shell type 3 passes wetback oil/gas fired boiler. After fuel is being atomized by burner, flame is full of the wave furnace and transfer heat via furnace wall, this is 1st pass; the high temperature smoke is collected in reversal chamber and then enters 2nd pass which is grooved tubes bundle area; after heat convection, air temperature gradually falls and goes to front smoke box and turn to 3rd pass, which is smooth tubes bundle area, and then enters chimney passing back smoke box and exhausted to the atmosphere.

Technical advantages:

1. Digitized manufacture
The key part such as material cutting, rolling, drilling are proceeded by advanced CNC machining process to reduce the assemble stress and extend boiler working lifetime.
The front and back smoke chamber plates are cut by CNC plasma cutting machine and looks tidy and beautiful.

2.Easy operation and maintenance
Fully automatically operating, with automatically adjustment and protection of burning, water level, temperature and steam pressure.

3. Longer working life
Smoke tube and tube sheet connection is expanded first to eliminate the gap between them, then adopt automatic argon arc welding to relief the stress and expand boilers working life.
Longitudinal and girth joint adopt advanced automatic submerged-arc welding for good welding quality. All longitudinal and girth joint will have 100% radiographic inspection.
Fin tube us ND steel or stainless-steel material which avoid low temperature corrosion.
Inspection procedure point is set up to guarantee the sequence of expanding and welding, avoid cracking of the tube sheet holes.

4. Less fuel consumption
High quality aluminum silicate fiber is used with fire clay insulation, to control the boiler body temperature below 45℃ to control heat lost.
Sufficient steam storage room and heating area makes boiler to generate high quality steam and high thermal power.
Condenser is added to reuse the waste heat of the exhausted smoke to increase feeding water’s temperature and reduce emission temperature, which can increase the thermal efficiency above 98% and save operating cost.

Understanding Steam & Boiler Heating Systems | HomeAdvis

Boiler Systems Operation In steam heating systems, a boiler furnace heats water by means of a gas or oil-fired burner and turns it into steam. The steam travels through pipes to radiators or convectors, which give off heat and warm the room. As the steam cools, it condenses back into water, and returns to the boiler to be heated again.

Chapter 4104: BOILERS - Ohio Laws and Rul

Chapter 4104: BOILERS. and periodic testing and maintenance of controls and safety devices on an automatically operated boiler directly fired with gas, oil, gas-oil, or electricity or a stationary steam engine that would allow an owner to operate a low pressure steam boiler, power boiler, or a stationary steam engine without the presence of

Industrial boiler technology for beginne

How an industrial boiler system works The heart of an industrial boiler system is a hot water or steam boiler operated with a certain kind of fuel. The boiler heats up or evaporates the water inside it, which is then transported to the consumers via pipe systems. In case of hot water the transport energy is …

Home - PHC Par

The home and first choice for professional gas safe engineers, Major domestic and commercial boiler spares and heating spares stockist, plumbing and aircon spares, Ready for next day despatch.

Boiler (power generation) - Wikiped

A boiler or steam generator is a device used to create steam by applying heat energy to water.Although the definitions are somewhat flexible, it can be said that older steam generators were commonly termed boilers and worked at low to medium pressure (7–2,000 kPa or 1–290 psi) but, at pressures above this, it is more usual to speak of a steam generator.

Boilers at Lowes.c

Rinnai M-Series 60000-BTU Natural Gas Boiler A.O. Smith Signature 40-Gallon Short 6-year Limited 4500-Watt Double Element Electric Water Heater A.O. Smith Signature 50-Gallon Tall 6-Year Limited Natural Gas Water Heater

Swap gas boilers for hydrogen or miss - The Guardi

Nov 22, 2018· Millions of gas boilers will need to be replaced with hydrogen alternatives and coupled with electric heating devices if Britain is to hit its carbon targets at the lowest cost, according to the

Boiler Operation & Boiler Maintenance | HSB Locomoti

Boiler Operation and Maintenance. A stack temperature gage is normally installed on a boiler to indicate the temperature of the flue gas leaving the boiler. A high stack temperature indicates that the tubes may be getting a buildup of soot or scale. Often, a boiler is operated with the isolation valves to the gage glass closed because

Natural Gas - Boilers - Heaters - The Home Dep

Rand and Reardon RRG 84% AFUE Natural Gas Water Boiler with 100,000 BTU Input and 73,000 Output

GAS OPERATED BOIL

An explanation of how the control system operates on automatic gas boilers follows: After the boiler is filled with water to the proper level and the fuel switch is turned ON, the main gas valve will be activated allowing gas to flow to the main burners that will be ignited by the Spark Pilot. When the boiler builds to

Furnaces and Boilers | Department of Ener

Gas-Fired Furnaces and Boilers (includes units fired with natural gas and propane) Oil-Fired Furnaces and Boilers . Other retrofitting options that can improve a system's energy efficiency include installing programmable thermostats , upgrading ductwork in forced-air systems, and adding zone control for hot-water systems, an option discussed in

Contact Us

zhulin@zozen.com

No. 76, Xin Da Road, Zhou tie Town, Yixing, Wuxi, China

0086-510-68530066, +86-13506151292

Get Latest Price
Get in Touch

If you have any problems about our product and service,please feel free to give your inquiry in the form below. We will reply you within 24 hours as soon as possible.Thank you!

  • Boiler type
  • Name
  • email
  • Phone or Whatsapp
  • message
I accept the Data Protection Declaration

Copyright © 2020.Zhongzheng Boiler Co., ltd. All rights reserved.

top